Browse all practice questions for the Spriggs Essentials Sleep Technicians Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Dream Big in 2026: Ace the Spriggs Essentials Sleep Technicians Exam! course image
All questions

These questions are part of the practice quiz. Start practicing

  • Which action is essential before beginning a sleep study to ensure accurate results?
  • Which condition is characterized by excessive daytime sleepiness?
  • What is the correct setting for EOG filters as per standard practice?
  • What is the definition of sleep latency?
  • In the context of sleep disorders, what is hypersomnia?
  • What type of artifact is commonly caused by patient movement during a sleep study?
  • Which of these electrode sites is not typically used in a baseline montage?
  • What should a sleep technician do first to ensure the proper test is being performed?
  • What is the primary purpose of using a high-frequency filter in polysomnography?
  • In relation to EEG, what does the term 'amplitude' represent?
  • What may happen if sleep is consistently fragmented?
  • In relation to the measurement from Cz to T4, how far is T5 if T5 is 3.5 cm closer to Cz than T4?
  • What is a major difference between AC and DC amplifiers?
  • What signifies REM sleep in a sleep study?
  • What is the role of the hypothalamus in sleep regulation?
  • In measuring the vertical distance on the head, what reference points would be critical?
  • In which sleep phase does most dreaming occur?
  • What term describes the rate at which a wave repeats itself or oscillates?
  • If a low wave artifact is detected, what is a potential consequence?
  • What is the most likely cause of a high-amplitude, low-frequency artifact in an EEG channel?
  • What is a primary characteristic of obstructive sleep apnea?
  • The recording of eye movements is based on which electrical potential difference?
  • What are the primary sleep phases measured during a sleep study?
  • What is the typical duration of a diagnostic polysomnography study?
  • What is the primary focus of observing respiratory patterns during a sleep study?
  • Which environmental factor can negatively impact sleep quality?
  • Which of the following is not true of muscle artifact?
  • What is the recommended impedance level for EEG electrodes?
  • In which way can lifestyle changes enhance sleep quality?
  • Which variable is crucial for accurate EEG frequency calculations?
  • During the night, the technician notices a gradual decline of the SpO2 by 8%. Which of the following would help determine the cause of this event?
  • What is the distance from Fp2 to F8?
  • Which scenario is most likely to cause electrode popping?
  • What effects can chronic sleep deprivation have on physical health?
  • What is the distance from F3 to Fz if the measurement from F7 to F3 is 6 cm?
  • What is a possible effect of caffeine consumption late in the day?
  • How does excessive noise in the environment during sleep affect a person?
  • What common recommendation is made for improving sleep hygiene?
  • Which factor is significant in determining an individual's ability to fall asleep?
  • Which factors can contribute to circadian rhythm disorders?
  • If F7 to F3 measures 6 cm, what would be the significance of this measurement in terms of cortex lead placements?
  • Which measurement is affected by the impedance of the skin?
  • How can excessive daytime sleepiness affect work performance?
  • What is essential for ensuring the integrity of signal derivations in a sleep study?
  • What is the primary goal of maintaining a sleep diary?
  • How should sleep technicians provide patient education on sleep hygiene?
  • Which adjunct therapy is commonly associated with managing insomnia?
  • Which phase of sleep is primarily associated with dreaming?
  • Which electrode site is located 10% above the inion?
  • Which of these is considered a DC channel?
  • What is a characteristic of slow-frequency artifact appearing in an EEG channel?
  • With a head circumference of 60 cm, what is the distance from O2 to T4?
  • Which of the following therapies focuses on behavioral changes to improve sleep?
  • If the distance from T6 to Pz is stated as 8 cm, how far is it from C3 to Pz?
  • What is REM sleep important for?
  • Which equation correctly represents sensitivity in EEG recordings?
  • What is indicated by the output signal of a differential amplifier when both inputs are identical?
  • What is the primary purpose of the low-frequency filter in polysomnography?
  • In polysomnography, what does the sensitivity setting refer to?
  • What is the distance from T3 to Oz if the circumference of the patient's head is 50 cm?
  • Why is monitoring oxygen saturation critical during sleep studies?
  • What effect does adjusting the sensitivity from 5 μV/mm to 10 μV/mm have?
  • What is a disadvantage of using a gold cup electrode?
  • What distinguishes central sleep apnea from obstructive sleep apnea?
  • Which electrode site is half the distance from T3 to T4?
  • What factor is most likely to cause a 60-Hz artifact?
  • What percentage of the vertical measurement of the head (nasion to inion) is Pz from the inion?
  • Typical findings in a sleep study for periodic limb movement disorder include?
  • If the measured distance from the nasion to the inion is 36 cm, what is the distance from Cz to Pz?
  • According to polarity convention, an eye movement to the right should result in which pen deflection across the electrodes?
  • What can occur from referencing electrodes with dissimilar metals to each other?
  • The measured distance from pre-auricular to pre-auricular is 40 cm. What is the distance from Cz to C3?
  • What does polysomnography primarily measure?
  • What is the primary function of a sleep technician?
  • What is the primary function of a CPAP machine?
  • Which artifact may be observed during an EEG recording?
  • What role does the reticular activating system (RAS) play in sleep?
  • How is the amplitude of a wave determined in polysomnography?
  • How far is C3 from T5 if the distance from Cz to C3 is 6 cm and C3 to T5 is 3 cm?
  • What role does sleep hygiene education play in improving sleep?
  • If the low-frequency filter is increased from 0.3 Hz to 1 Hz in an EEG channel, what is the effect?
  • What is the distance from the left pre-auricular point to T3 if the distance from pre-auricular point to pre-auricular point is 36 cm?
  • What filter setting is typically appropriate for ECG monitoring?
  • What is an indicator of sleep-disordered breathing during a sleep study?
  • Which of these is the best sensitivity setting for an EEG channel?
  • What is associated with the physiologic effects of sleep deprivation?
  • What is a typical instruction for patients before a sleep study?
  • What is the recommended treatment for obstructive sleep apnea?
  • Which age group is most commonly affected by restless legs syndrome (RLS)?
  • How does the circadian rhythm affect sleep?
  • Amplitude is primarily a measure of which quantity?
  • During a sleep study, what is a priority if multiple artifacts arise simultaneously?
  • If G1 = −80 μV and the output voltage is 20 μV, what is the voltage at G2?
  • What are common comorbidities associated with sleep apnea?
  • In the case of a constant artifact in multiple channels, what is the most advisable action?
  • What type of equipment is primarily used to monitor brain activity during a sleep study?
  • What is the primary function of a high-frequency filter?
  • When using a sensitivity setting of 5 µV/mm, how much pen deflection is produced by a 75-µV signal?
  • What is the optimal method of correcting undesirable artifacts when the patient is asleep?
  • When reviewing an EEG, which element would you assess first for signal quality?
  • What is a primary goal of cognitive behavioral therapy for insomnia (CBT-I)?
  • The quality and accuracy of a sleep recording is mostly determined by?
  • What should be done if a mixed-frequency artifact appears due to a faulty electrode without a backup derivation available?
  • Which organization is the leading authority in sleep medicine?
  • Which condition is likely to cause slow wave artifact in the EEG or EOG channels?
  • What is a nocturnal oximetry test primarily used for?
  • What is the distance from O2 to Fz if the distance from O1 to Fz is 8 cm?
  • What are key components of a sleep study report?
  • Which of these settings is preferred for the HFF in an EMG channel?
  • Changing the sensitivity setting in EEG causes what effect?
  • What aspect of sleep might be tracked with a sleep study?
  • Which of the following is a primary symptom of insomnia?
  • What is the role of REM sleep in overall health?
  • When the measured distance from Cz to T4 is 14 cm, what is the distance from C4 to T4?
  • Amplitude is a measurement of the what of a waveform, whereas frequency is a measurement of the what of a waveform?
  • Tracing the signal pathway from the patient to the output of the polysomnograph can be beneficial for:
  • What is the role of the prefrontal cortex during sleep?
  • How can the frequency of an EEG signal be determined?
  • Which one or more of the following statements is true regarding notch filters?
  • Which of the following is a potential outcome of reduced sleep quality?
  • How does obesity relate to sleep apnea?
  • How is sleep apnea primarily diagnosed?
  • During a sleep study, what does a high arousal index indicate?
  • What may cause a strong ECG artifact in an EMG channel?
  • Where should the chin EMG electrodes be placed?
  • Which age group is most likely to experience sleep disturbances?
  • What role does temperature play in achieving quality sleep?
  • What is actigraphy and how is it used?
  • Which of these HFF settings is preferred in the airflow channel?
  • What is one of the key indicators monitored to assess sleep apnea?
  • What is a common feature when documenting eye movements in EEG?
  • A ground loop may occur when:
  • When determining electrode placements, which two points are crucial for accurate measurement?
  • If both G1 and G2 receive an input of 50 μV, what is the expected output signal?
  • If the measurement from T6 to Pz is 8 cm, what is the distance from P4 to Pz?
  • What are some common signs of sleep apnea?
  • What is a characteristic symptom of restless legs syndrome (RLS)?
  • If a 60-Hz artifact is present during physiologic calibrations, what should the technologist do?
  • Given a patient's head circumference of 56 cm, what is the distance from Oz to O1?
  • If G1 and G2 both equal −25 μV, what is the output voltage?
  • What is an appropriate sensitivity setting for an EEG channel?
  • Which of the following are common types of sleep studies performed?
  • What type of wire is best for recording EEG activity?
  • Which symptom is commonly associated with sleep apnea?
  • A stress loop can be most beneficial when applying which electrodes?
  • What are parasomnias?
  • Why is it important to analyze sleep architecture?
  • In terms of patient comfort, which of the following is an important consideration during polysomnography?
  • Which muscle are the leg EMG electrodes placed on?
  • When the patient looks up, what will the waves on the E2 and E1 channels do?
  • What are the potential consequences of untreated insomnia?
  • If G1 receives a signal of −100 μV while G2 receives −50 μV, what is the output signal?
  • Which electrode site is located half the distance between Fp2 and C4?
  • Which hormone is key in regulating sleep-wake cycles?
  • What happens to the channels when a patient looks right?
  • How does age affect sleep patterns?
  • Which filter settings are most appropriate for the EEG?
  • Which medical professional typically interprets the results of a polysomnography study?
  • Which type of medication is known to cause sleep disturbances?
  • If G1 = 60 μV and G2 = 10 μV, what is the output signal voltage?
  • Which electrode site is located half the distance from O2 to C4?
  • In which of these channels is the shape of the waves most important?
  • What type of device is commonly used to measure airflow during sleep?
  • What filter settings are best for recording EMG channels?
  • The polysomnograph has a leakage current of 200 μA. What should the technician do about this?
  • A sleep study usually includes all but which of the following measurements?
  • What approach may be taken if a patient has both insomnia and sleep apnea?
  • The distance from Fp1 to O1 through C3 is 24 cm. What is the distance from C3 to P3?
  • What is a common approach to improving sleep hygiene?
  • What does cognitive behavioral therapy for insomnia (CBT-I) focus on?
  • Which EEG electrode site is half the distance from F8 to Fz?
  • What is the distance from P4 to T4 if the distance from O2 to P4 is 10 cm?
  • What is the primary purpose of an EEG?
  • What type of sleep disorder may cause inadequate REM sleep?
  • Wires attached to the patient may be dangerous if:
  • Which filter settings should be used for recording airflow and respiratory effort?
  • Which filter settings are most appropriate for EEG channels in a sleep study?
  • What should be done if a slow wave artifact appears in three EEG channels sharing a common reference?
  • How does smoking affect sleep quality?
  • What does the apnea-hypopnea index (AHI) measure?
  • Which of these montages includes the use of a thermal and pressure channel to measure airflow?
  • Which of the following is a common symptom of sleep apnea?
  • If the measured distance from the nasion to the inion is 32 cm, what is the distance from the inion to Oz?
  • The symbol "G1" in polysomnography represents what?
  • What percentage of the circumference of the head is T5 from T3?
  • What is the recommended position for a patient with obstructive sleep apnea?
  • What is one indicator that a person may have sleep apnea?
  • What is the primary symptom of narcolepsy?
  • Which of these montages typically includes a full or expanded EEG hookup?
  • Which electrode site is half the distance from Fp2 to T4?
  • What benefit does maintaining a consistent sleep schedule provide?
  • Which of these LFF settings is preferred for an EEG channel?
  • How can sleep technicians ensure patient comfort during polysomnography?
  • If Cz to Pz measures 7.2 cm, what is the distance from T4 to Pz given that T4 is 4.2 cm from Cz?
  • A change in sensitivity produces a change in the?
  • What does an electroencephalogram (EEG) assess in individuals?
  • What is the primary aim of continuous positive airway pressure (CPAP) therapy?
  • The exploring electrode detects a voltage of −20 μV. The output voltage is 50 μV. What voltage did the reference electrodes detect at this time?
  • What is the expected movement of the E1 and E2 channels on polysomnography when the patient looks up?
  • What is the best method for correcting a 60-Hz artifact in leg EMGs during physiologic calibrations?
  • Which of the following can be a symptom of insomnia?
  • Electrical interference can best be prevented if which of the following actions is taken?
  • What effect does caffeine have on sleep onset?
  • How does sleep deprivation affect cognitive performance?
  • The frequency of a waveform can be altered by adjusting its?
  • Which of the following actions should the technologist not take in response to a low amplitude in the airflow channel?
  • What is the consequence of sleep fragmentation?
  • What does an increase in the low-frequency filter setting likely affect?
  • Which of these HFF settings is preferred in an EEG channel?
  • If a high-frequency artifact appears in a single EEG channel that shares a reference with other channels, what should be done?
  • Which therapy is often recommended for improving insomnia?
  • What does an EMG monitor during a sleep study?
  • Which of the following describes the function of a differential amplifier?
  • EEG amplitude is measured in which units, whereas EEG frequency is measured in which units?
  • What is the best practice for managing a high-frequency artifact if it only appears in one channel?
  • Why is it crucial to incorporate behavioral strategies in sleep therapy?
  • Which EEG electrode site is half the distance from O1 to T3?
  • What distance corresponds to the location Pz when measured from the inion?
  • How is obstructive sleep apnea primarily diagnosed?
  • Which of these sensors generates its own voltages and may be plugged directly into the head box?
  • What does the term 'montage' refer to in EEG?
  • The low-frequency filter in an EEG system is most closely associated with which aspect?
  • Which of these electrodes is located 20% of the horizontal measurement of the head (pre-auricular point to pre-auricular point) to the left of Cz?
  • What is the standard paper speed used for a sleep study?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy